CDNEXT (Common Mode to Differential Mode Near-End Xtalk) - DSX CableAnalyzer

CDNEXT is a troubleshooting tool only at this time for Channel Alien Xtalk testing issues. There are no test limits in ANSI/TIA-568-C.2, ANSI/TIA-1005 or ISO/IEC 11801:2010. However, you will find it discussed in TIA-TSB-1197.

Poor CDNEXT is primarily a connector choice issue. Although unlikley, it could be a workmanship issue too.

The measurement is made by injecting a differential mode signal (DM) into one twisted pair, then measuring the common mode signal (CM) on another pair. The smaller the CM signal returned, the better the CDNEXT.
 
             DSX CableAnalyzer Common Mode Measurement

If it looks similar to a NEXT measurement, you're right. Except a NEXT measurement is made by injecting a DM signal onto one pair and measuring the DM signal on another pair. Here we are measuring the CM signal on the other pair, which is CDNEXT.

Other balance measurements such as TCL, ELTCTL and CMRL are also available in the DSX-5000 CableAnalyzer.

If you wish to add CDNEXT to your standard Category 5e, 6, 6A or Class D, E or EA test, select your test limit with a suffix of (+ALL):
 
         Testgrenzwert für alle TIA-Kategorien     Testgrenzwert für alle ISO-Kategorien         

Dies erhöht Ihre AUTOTEST-Zeit.

The suffix of (+All) indicates a standard ANSI/TIA or ISO/IEC test with the addition of ELTCTLTCLResistance Unbalance within a pairResistance Unbalance between pairs, CMRL and CDNEXT measurements. 
 
Im folgenden Beispiel von einem DSX-5000 CableAnalyzer wurde ein Kanal Kategorie-6A geprüft.
  
        DSX Cableanalyzer Symmetrie-Messanzeige