Re-Certifying Test Results
The LinkWare PC re-certification feature lets you reevaluate existing test results against different test standards and NVP or IR values. The re-certification tool produces new test records that use the original cable IDs, but have new test times and dates.
You can recertify these types of results:
- Twisted pair certification results that include plot data.
- Fiber certification results that include loss and length measurements. This does not include OTDR results or results from SimpliFiber Pro or MultiFiber Pro meters.
Hinweis: The names of some twisted pair measurements have changed in the IEEE standards.
To re-certify test results
- In LinkWare PC, Select the records you want to re-certify.
- Select Utilities > Re-Certify.
- Follow the instructions given in the Re-Certification dialog box.
LinkWare PC saves re-certified records as new records in the database and adds "(RC)" to the original cable ID.
Always check with your customer first for acceptance of re-certified results.
- Acceptance of test results is up to your customer and the requirements of the job. Get agreement before you begin testing the job, or you may be forced to retest!
- Some limits are not available for re-certify if the limit used during initial testing did not scan to the same frequency ranges. For example, you cannot re-certify a TIA Cat 6 Perm. Link (scans to 350 MHz) result to TIA Cat 6A Perm. Link (scans to 500MHz).
Copper Re-Certification Example
Choose the desired test limit to re-evaluate the cable against.
You can choose to keep the test limit the same and change only the NVP.
When you press NEXT, LinkWare PC will evaluate the result and show Pass or Fail. Click Finish to add the RC result to your project.
The time/date on the RC result reflects when the re-certify process occurred.
See Also NVP incorrectly set in tester - does it matter
Fiber Re-Certification to Custom Limits
In addition to the regular fiber certification limits, there is also a configurable Custom Limit you may use to re-certify fiber results to custom loss limits at each wavelength and custom length limits you specify.
You may configure each of the fields below the highlighted line to enter your custom limits.
Change IR lets you change the index or refraction setting for the fiber result, and this parameter is used to calculate the length of the cable.
When you press NEXT, LinkWare PC will evaluate the result and show Pass or Fail. Click Finish to add the RC result to your project.
The time/date on the RC result reflects when the re-certify process occurred.