Statement of Volatility - MicroScanner2

 

Datum: 1. März 2016

 

Statement of Memory Volatility

 

Product and Manufacturer

Modelle:

MicroScanner2 Cable Verifier

Manufacturer:  FLUKE NETWORKS

Adresse:  6920 Seaway Blvd.

Ort:  Everett

Staat:  WA

Plz:  98203

Telefon:  800-283-5853

Volatile Memory

Does the item contain volatile memory (i.e., memory whose contents are lost when power is removed)?

  Ja                   No                  (If the answer is ‘Yes’, provide the following information for each type of memory.)

Memory Type
 (SRAM, DRAM, etc.):

Größe:

User Modifiable:

Function:

Process to Clear:

SRAM

2 KBytes

  Ja         Nein

CPU RAM for stack

Turn unit off.

 


 

 

Non-Volatile Memory

Does the item contain non-volatile memory (i.e., memory whose contents are retained when power is removed)?

  Ja                   No                  (If the answer is ‘Yes’, provide the following information for each type of memory.)

Memory Type (BBRAM, Flash, EEPROM, etc.):

Größe:

User Modifiable:

 

Function:

Process to Clear:

Internal CPU FLASH

60 KBytes

  Ja         Nein

Main program memory and user set Nominal Velocity of Propagation

None.

Medium

Does the item contain media storage capability (i.e., removable or non-removable disk drives, memory cards, etc.)?

  Ja                   No                  (If the answer is ‘Yes’, provide the following information for each type of memory.)

Sub-Item:

Storage Type
(Disk, Tape, etc.):

Größe:

User Modifiable:

Function:

Process to Clear:

 

 

 

  Ja         Nein

 

 

Zusätzlicher Hinweis

This is a simple cable tester.  FLASH memory is used for program storage and is modified in one instance to store a simple 16 bit number which is used as a calibration factor (called the Nominal Velocity of Propagation).  This factor is used to correct the length measurement of a cable.  RAM memory is used as operating memory and stack while the unit is running.